ISVR
50.93556
-1.39282
19
442761
115299
elec/b19/ekw
Bldg 19 (ISVR)
2007
POLYGON((-1.39313923280514 50.9354851665757,-1.39297834453775 50.9357212920631,-1.39255721433256 50.9356073903953,-1.39271810259994 50.9353712643295,-1.39313923280514 50.9354851665757))
Highfield Campus
University of Southampton
Building 19 is non-residential
Wilson Mason Architects
A
50.93552
-1.39312
Electrodynamic Shakers
The Human Factors Research Unit laboratory has a wide range of electrodynamic vibrators of varying displacements up to 50 mm. Smaller vibrators are suitable for hand-arm vibration studies while the larger vibrators are capable of supporting a person while applying a vibration.
F10056
The Human Factors Research Unit laboratory has a wide range of electrodynamic vibrators of varying displacements up to 50 mm. Smaller vibrators are suitable for hand-arm vibration studies while the larger vibrators are capable of supporting a person while applying a vibration.
The Human Factors Research Unit laboratory has a wide range of electrodynamic vibrators of varying displacements up to 50 mm. Smaller vibrators are suitable for hand-arm vibration studies while the larger vibrators are capable of supporting a person while applying a vibration.
false
Multi Axis Man Rated 6 D.O.F. Vibration Seat System
E10573
Treadmill
E10575
6-Axis
The 6-axis Motion Simulator is able to provide motion in all three translation axes (fore-and-aft, lateral, and vertical) and all three rotational axes (roll, pitch, and yaw). The moving platform is approximately 3 meter by 2 meter and can support payloads up to 1000 kg. It is able to accurately reproduce motions in 6-axis with very low levels of background vibration, waveform distortion, and cross-axis motion.
F10052
The 6-axis Motion Simulator is able to provide motion in all three translation axes (fore-and-aft, lateral, and vertical) and all three rotational axes (roll, pitch, and yaw). The moving platform is approximately 3 meter by 2 meter and can support payloads up to 1000 kg. It is able to accurately reproduce motions in 6-axis with very low levels of background vibration, waveform distortion, and cross-axis motion.
The 6-axis Motion Simulator is able to provide motion in all three translation axes (fore-and-aft, lateral, and vertical) and all three rotational axes (roll, pitch, and yaw). The moving platform is approximately 3 meter by 2 meter and can support payloads up to 1000 kg. It is able to accurately reproduce motions in 6-axis with very low levels of background vibration, waveform distortion, and cross-axis motion.
false
1m Vertical
This vibrator is a single-axis human-rated electro-hydraulic vibrator used to provide vertical oscillation.
F10053
This vibrator is a single-axis human-rated electro-hydraulic vibrator used to provide vertical oscillation.
This vibrator is a single-axis human-rated electro-hydraulic vibrator used to provide vertical oscillation.
false
1m Horizontal
This single-axis human-rated electro-hydraulic vibrator is used to provide horizontal oscillation.
F10054
This single-axis human-rated electro-hydraulic vibrator is used to provide horizontal oscillation.
This single-axis human-rated electro-hydraulic vibrator is used to provide horizontal oscillation.
false
19m Simulator
[Await description]
F10055
[Await description]
[Await description]
false
Indenter Rig
The indenter rig can be used to measure the dynamic stiffness of seat cushions and the dynamic characteristics of suspension seat components such as dampers and springs. It may be used to conduct a quasi-static compression test for measuring load-deflection curves of seat cushions.
F10057
The indenter rig can be used to measure the dynamic stiffness of seat cushions and the dynamic characteristics of suspension seat components such as dampers and springs. It may be used to conduct a quasi-static compression test for measuring load-deflection curves of seat cushions.
The indenter rig can be used to measure the dynamic stiffness of seat cushions and the dynamic characteristics of suspension seat components such as dampers and springs. It may be used to conduct a quasi-static compression test for measuring load-deflection curves of seat cushions.
false
19 / 3007
Room 3007, Building 19
Building 19 / Level 1
1
Building 19 / Level 2
2
Building 19 / Level 3
Floor 3, Building 19
3
19 / 1023
1023
19 / 2039
2039
19 / 3013
3013
19 / 1039
1039
Shower (accessible)
50.93556
-1.39282
shower2
2010
66
100
1.5151515151515
2518
2010
666
1000
1.5015015015015
99204
2010
1066
1600
1.5009380863039
219527
2010
1280
1920
1.5
297210
2010
133
200
1.5037593984962
6728
2010
220
220
1
10182
2010
260
240
0.92307692307692
12159
2010
200
300
1.5
12915
2010
198
320
1.6161616161616
13638
2010
266
400
1.5037593984962
20890
2010
297
480
1.6161616161616
27149
2010
33
50
1.5151515151515
1273
2010
400
600
1.5
41170
2010
533
800
1.5009380863039
67559
2010
600
800
1.3333333333333
72291
2010
2304
3456
1.5
3540763