rdfs:label "High Performance Liquid Chromatography Mass Spectrometer (HPLC-MS)"^^xsd:string
dcterms:description "High Performance Liquid Chromatography Mass Spectrometer (HPLC-MS). LC-MSn offers Trap-HCD (Higher-Energy Collisional Dissociation) combined with CID (Collision-Induced Dissociation), PQD* (Pulsed-Q Dissociation) and ETD (Electron Transfer Dissociation) to solve the most difficult analytical problems. Key Features:[nl]
 - Novel wide dynamic range discrete dynode detection system provides up to six orders of linear quantitation[nl]
- Unique dual-pressure linear ion trap simultaneously increases scan speed and mass resolution[nl]
- Proprietary S-lens ion optics increase ion transmission and shorten trap fill time, improving instrument sensitivity and data acquisition rate[nl]
- Generation II ion optics improve robustness and reduces downtime[nl]
- Trap-HCD functionality combined with CID, PQD and ETD provides the ultimate in structural information[nl]
- Predictive Automatic Gain Control reduces cycle times, yielding improved data acquisition rates."^^xsd:string
skos:notation "E10192"^^http://id.southampton.ac.uk/ns/equipment-code-scheme
http://data.ordnancesurvey.co.uk/ontology/spatialrelations/within http://id.southampton.ac.uk/building/68
rdfs:comment "High Performance Liquid Chromatography Mass Spectrometer (HPLC-MS). LC-MSn offers Trap-HCD (Higher-Energy Collisional Dissociation) combined with CID (Collision-Induced Dissociation), PQD* (Pulsed-Q Dissociation) and ETD (Electron Transfer Dissociation) to solve the most difficult analytical problems. Key Features:[nl]
 - Novel wide dynamic range discrete dynode detection system provides up to six orders of linear quantitation[nl]
- Unique dual-pressure linear ion trap simultaneously increases scan speed and mass resolution[nl]
- Proprietary S-lens ion optics increase ion transmission and shorten trap fill time, improving instrument sensitivity and data acquisition rate[nl]
- Generation II ion optics improve robustness and reduces downtime[nl]
- Trap-HCD functionality combined with CID, PQD and ETD provides the ultimate in structural information[nl]
- Predictive Automatic Gain Control reduces cycle times, yielding improved data acquisition rates."^^xsd:string
oo:contact http://id.southampton.ac.uk/equipment/E10192#secondary_contact
foaf:page http://www.noc.soton.ac.uk/geochem/Facilities%20Links/tims.htm
dc:description "High Performance Liquid Chromatography Mass Spectrometer (HPLC-MS). LC-MSn offers Trap-HCD (Higher-Energy Collisional Dissociation) combined with CID (Collision-Induced Dissociation), PQD* (Pulsed-Q Dissociation) and ETD (Electron Transfer Dissociation) to solve the most difficult analytical problems. Key Features:[nl]
 - Novel wide dynamic range discrete dynode detection system provides up to six orders of linear quantitation[nl]
- Unique dual-pressure linear ion trap simultaneously increases scan speed and mass resolution[nl]
- Proprietary S-lens ion optics increase ion transmission and shorten trap fill time, improving instrument sensitivity and data acquisition rate[nl]
- Generation II ion optics improve robustness and reduces downtime[nl]
- Trap-HCD functionality combined with CID, PQD and ETD provides the ultimate in structural information[nl]
- Predictive Automatic Gain Control reduces cycle times, yielding improved data acquisition rates."^^xsd:string
oo:formalOrganization http://id.southampton.ac.uk/
oo:organizationPart http://id.southampton.ac.uk/org/F6, http://id.southampton.ac.uk/org/HN
oo:primaryContact http://id.southampton.ac.uk/equipment/E10192#primary_contact
oo:relatedFacility http://id.southampton.ac.uk/facility/F10090
 
http://id.southampton.ac.uk/building/68
rdf:type http://vocab.deri.ie/rooms#Building, http://id.southampton.ac.uk/ns/UoSBuilding
rdfs:label "National Oceanography Centre"^^xsd:string
is http://data.ordnancesurvey.co.uk/ontology/spatialrelations/within of http://id.southampton.ac.uk/equipment/E10192
 
http://id.southampton.ac.uk/equipment/E10192#secondary_contact
rdf:type foaf:Person
is oo:contact of http://id.southampton.ac.uk/equipment/E10192
 
http://id.southampton.ac.uk/
rdf:type http://purl.org/vocab/aiiso/schema#Institution, http://www.w3.org/ns/org#FormalOrganization, http://www.w3.org/ns/org#Organization, foaf:Organization
rdfs:label "University of Southampton"^^xsd:string
is oo:formalOrganization of http://id.southampton.ac.uk/equipment/E10192
 
http://id.southampton.ac.uk/org/F6
rdf:type http://www.w3.org/ns/org#OrganizationalUnit, http://www.w3.org/ns/org#Organization
rdfs:label "Faculty of Natural and Environmental Sciences"^^xsd:string
is oo:organizationPart of http://id.southampton.ac.uk/equipment/E10192
 
http://id.southampton.ac.uk/org/HN
rdf:type http://www.w3.org/ns/org#Organization
rdfs:label "School of Ocean and Earth Science"^^xsd:string
is oo:organizationPart of http://id.southampton.ac.uk/equipment/E10192
 
http://id.southampton.ac.uk/equipment/E10192#primary_contact
rdf:type foaf:Agent
foaf:name "WHITESIDE, JESSICA"^^xsd:string
is oo:primaryContact of http://id.southampton.ac.uk/equipment/E10192