→ rdfs:label → "Thermo Accela HPLC/LTQ Velos MS"^^xsd:string
→ dcterms:description → "High Performance Liquid Chromatography Mass Spectrometer (HPLC-MS). LC-MSn offers Trap-HCD (Higher-Energy Collisional Dissociation) combined with CID (Collision-Induced Dissociation), PQD* (Pulsed-Q Dissociation) and ETD (Electron Transfer Dissociation) to solve the most difficult analytical problems. Key Features:[cr][nl]
- Novel wide dynamic range discrete dynode detection system provides up to six orders of linear quantitation[cr][nl]
- Unique dual-pressure linear ion trap simultaneously increases scan speed and mass resolution[cr][nl]
- Proprietary S-lens ion optics increase ion transmission and shorten trap fill time, improving instrument sensitivity and data acquisition rate[cr][nl]
- Generation II ion optics improve robustness and reduces downtime[cr][nl]
- Trap-HCD functionality combined with CID, PQD and ETD provides the ultimate in structural information[cr][nl]
- Predictive Automatic Gain Control reduces cycle times, yielding improved data acquisition rates."^^xsd:string
→ skos:notation → "E10655"^^http://id.southampton.ac.uk/ns/equipment-code-scheme
→ rdfs:comment → "High Performance Liquid Chromatography Mass Spectrometer (HPLC-MS). LC-MSn offers Trap-HCD (Higher-Energy Collisional Dissociation) combined with CID (Collision-Induced Dissociation), PQD* (Pulsed-Q Dissociation) and ETD (Electron Transfer Dissociation) to solve the most difficult analytical problems. Key Features:[cr][nl]
- Novel wide dynamic range discrete dynode detection system provides up to six orders of linear quantitation[cr][nl]
- Unique dual-pressure linear ion trap simultaneously increases scan speed and mass resolution[cr][nl]
- Proprietary S-lens ion optics increase ion transmission and shorten trap fill time, improving instrument sensitivity and data acquisition rate[cr][nl]
- Generation II ion optics improve robustness and reduces downtime[cr][nl]
- Trap-HCD functionality combined with CID, PQD and ETD provides the ultimate in structural information[cr][nl]
- Predictive Automatic Gain Control reduces cycle times, yielding improved data acquisition rates."^^xsd:string
→ dc:description → "High Performance Liquid Chromatography Mass Spectrometer (HPLC-MS). LC-MSn offers Trap-HCD (Higher-Energy Collisional Dissociation) combined with CID (Collision-Induced Dissociation), PQD* (Pulsed-Q Dissociation) and ETD (Electron Transfer Dissociation) to solve the most difficult analytical problems. Key Features:[cr][nl]
- Novel wide dynamic range discrete dynode detection system provides up to six orders of linear quantitation[cr][nl]
- Unique dual-pressure linear ion trap simultaneously increases scan speed and mass resolution[cr][nl]
- Proprietary S-lens ion optics increase ion transmission and shorten trap fill time, improving instrument sensitivity and data acquisition rate[cr][nl]
- Generation II ion optics improve robustness and reduces downtime[cr][nl]
- Trap-HCD functionality combined with CID, PQD and ETD provides the ultimate in structural information[cr][nl]
- Predictive Automatic Gain Control reduces cycle times, yielding improved data acquisition rates."^^xsd:string