→ rdfs:label → "Imaging & Microscopy Centre"^^xsd:string
→ dcterms:description → "The Imaging and Microscopy Centre (IMC) is a core facility specialising in light microscopy applications, in particular confocal and multiphoton microscopy. Its equipment allows to combine confocal and widefield fluorescence microscopy with electrophysiology. IMC is inter-linked with the Institute for Life Sciences with which it co-operates in providing specialist imaging applications and imaging expertise. The Centre has an open access policy for internal and external users and offers training courses as well as one-to-one training sessions for operating its equipment. The IMC space comprises containment level (CL) 1 and 2 areas, including a CL 2 preparation room, and is managed by Mark Willett (facility manager) according to a local code of practice"^^xsd:string
→ skos:notation → "F10033"^^http://id.southampton.ac.uk/ns/equipment-code-scheme
→ rdfs:comment → "The Imaging and Microscopy Centre (IMC) is a core facility specialising in light microscopy applications, in particular confocal and multiphoton microscopy. Its equipment allows to combine confocal and widefield fluorescence microscopy with electrophysiology. IMC is inter-linked with the Institute for Life Sciences with which it co-operates in providing specialist imaging applications and imaging expertise. The Centre has an open access policy for internal and external users and offers training courses as well as one-to-one training sessions for operating its equipment. The IMC space comprises containment level (CL) 1 and 2 areas, including a CL 2 preparation room, and is managed by Mark Willett (facility manager) according to a local code of practice"^^xsd:string
→ dc:description → "The Imaging and Microscopy Centre (IMC) is a core facility specialising in light microscopy applications, in particular confocal and multiphoton microscopy. Its equipment allows to combine confocal and widefield fluorescence microscopy with electrophysiology. IMC is inter-linked with the Institute for Life Sciences with which it co-operates in providing specialist imaging applications and imaging expertise. The Centre has an open access policy for internal and external users and offers training courses as well as one-to-one training sessions for operating its equipment. The IMC space comprises containment level (CL) 1 and 2 areas, including a CL 2 preparation room, and is managed by Mark Willett (facility manager) according to a local code of practice"^^xsd:string
→ skos:notation → "85"^^http://id.southampton.ac.uk/ns/building-code-scheme
→ dcterms:spatial → "POLYGON((-1.39571622986069 50.9366911998832,-1.39565963599779 50.9367090886135,-1.39570311445755 50.9367731143608,-1.39541340777842 50.9369135064954,-1.39519260188158 50.9366390621206,-1.39496416030483 50.9363017786347,-1.39490037991966 50.9362076920698,-1.3949628128319 50.9361549876593,-1.3950845345529 50.9360662788121,-1.39513187576837 50.936073411757,-1.39518766114752 50.9361762732286,-1.39544583696017 50.9361800661349,-1.3955537246258 50.936328895004,-1.39558974706869 50.9363744097095,-1.3956182236632 50.9364082626581,-1.39563951373543 50.9364319823515,-1.39557672149707 50.9364853091598,-1.39570482125659 50.9366073039108,-1.39571622986069 50.9366911998832))"^^xsd:string
← is
foaf:depicts of
← https://data.southampton.ac.uk/image-archive/buildings/100/85.jpg,
https://data.southampton.ac.uk/image-archive/buildings/1000/85.jpg,
https://data.southampton.ac.uk/image-archive/buildings/1600/85.jpg,
https://data.southampton.ac.uk/image-archive/buildings/1920/85.jpg,
https://data.southampton.ac.uk/image-archive/buildings/200/85.jpg,
https://data.southampton.ac.uk/image-archive/buildings/220x220/85.jpg,
https://data.southampton.ac.uk/image-archive/buildings/240x260/85.jpg,
https://data.southampton.ac.uk/image-archive/buildings/300/85.jpg,
https://data.southampton.ac.uk/image-archive/buildings/320x198/85.jpg,
https://data.southampton.ac.uk/image-archive/buildings/400/85.jpg,
https://data.southampton.ac.uk/image-archive/buildings/480x297/85.jpg,
https://data.southampton.ac.uk/image-archive/buildings/50/85.jpg,
https://data.southampton.ac.uk/image-archive/buildings/600/85.jpg,
https://data.southampton.ac.uk/image-archive/buildings/800/85.jpg,
https://data.southampton.ac.uk/image-archive/buildings/800x600/85.jpg,
https://data.southampton.ac.uk/image-archive/buildings/raw/85.jpg
→ rdfs:label → "Faculty of Natural and Environmental Sciences"^^xsd:string
→ rdfs:label → "School of Biological Sciences"^^xsd:string
→ skos:notation → "BJ"^^http://id.southampton.ac.uk/ns/alphaCode,
"A2BJ000000"^^http://id.southampton.ac.uk/ns/10CharHRCode
→ rdfs:label → "Li-Cor Biosciences Odyssey"^^xsd:string
→ dcterms:description → "Infrared imaging system for scanning and analysis of Western Blots, cell-based assays, gel stainings, protein assays and tissue sections[nl]
2 diode lasers (685 nm and 785 nm)[nl]
2 independent infrared detection channels[nl]
Odyssey Application Software"^^xsd:string
→ skos:notation → "E10094"^^http://id.southampton.ac.uk/ns/equipment-code-scheme
→ rdfs:comment → "Infrared imaging system for scanning and analysis of Western Blots, cell-based assays, gel stainings, protein assays and tissue sections[nl]
2 diode lasers (685 nm and 785 nm)[nl]
2 independent infrared detection channels[nl]
Odyssey Application Software"^^xsd:string
→ dc:description → "Infrared imaging system for scanning and analysis of Western Blots, cell-based assays, gel stainings, protein assays and tissue sections[nl]
2 diode lasers (685 nm and 785 nm)[nl]
2 independent infrared detection channels[nl]
Odyssey Application Software"^^xsd:string
→ rdfs:label → "Carl Zeiss Axiovert 200"^^xsd:string
→ dcterms:description → "Widefield fluorescence microscopy system with fixed stage and electrophysiology equipment:[nl]
upright stand ¿ Zeiss Axioskop 2 FS mot[nl]
Burleigh Gibraltar platform and XY- stage[nl]
HBO 100 incident light illuminator[nl]
DAPI, FITC and Rhodamine filter cubes for fluorescence microscopy[nl]
air objective (10x/0.30)[nl]
water dipping objectives (40x/0.80, 63x/0.90)[nl]
DIC optics[nl]
AxioCam MRm monochrome camera[nl]
AvioVision software for image acquisition and analysis[nl]
Warner Instruments recording chamber and dual automatic temperature controller[nl]
Burleigh PCS 5000 micromanipulator[nl]
Axon-Instruments Axoclamp 2B[nl]
Axon-Instruments Axopatch 200B[nl]
Axon-Instruments pClamp 9 data acquisition and analysis software for electrophysiology"^^xsd:string
→ skos:notation → "E10099"^^http://id.southampton.ac.uk/ns/equipment-code-scheme
→ rdfs:comment → "Widefield fluorescence microscopy system with fixed stage and electrophysiology equipment:[nl]
upright stand ¿ Zeiss Axioskop 2 FS mot[nl]
Burleigh Gibraltar platform and XY- stage[nl]
HBO 100 incident light illuminator[nl]
DAPI, FITC and Rhodamine filter cubes for fluorescence microscopy[nl]
air objective (10x/0.30)[nl]
water dipping objectives (40x/0.80, 63x/0.90)[nl]
DIC optics[nl]
AxioCam MRm monochrome camera[nl]
AvioVision software for image acquisition and analysis[nl]
Warner Instruments recording chamber and dual automatic temperature controller[nl]
Burleigh PCS 5000 micromanipulator[nl]
Axon-Instruments Axoclamp 2B[nl]
Axon-Instruments Axopatch 200B[nl]
Axon-Instruments pClamp 9 data acquisition and analysis software for electrophysiology"^^xsd:string
→ dc:description → "Widefield fluorescence microscopy system with fixed stage and electrophysiology equipment:[nl]
upright stand ¿ Zeiss Axioskop 2 FS mot[nl]
Burleigh Gibraltar platform and XY- stage[nl]
HBO 100 incident light illuminator[nl]
DAPI, FITC and Rhodamine filter cubes for fluorescence microscopy[nl]
air objective (10x/0.30)[nl]
water dipping objectives (40x/0.80, 63x/0.90)[nl]
DIC optics[nl]
AxioCam MRm monochrome camera[nl]
AvioVision software for image acquisition and analysis[nl]
Warner Instruments recording chamber and dual automatic temperature controller[nl]
Burleigh PCS 5000 micromanipulator[nl]
Axon-Instruments Axoclamp 2B[nl]
Axon-Instruments Axopatch 200B[nl]
Axon-Instruments pClamp 9 data acquisition and analysis software for electrophysiology"^^xsd:string